Basic Info.
Packaging & Delivery
Product Description
3-Zone Thermal Shock Test Chamber for Battery Laboratory Equipment
OEM &ODM are welcome
Main technical Specification

Technical specification
(1) KTS-A Series
| Model |
| ||||||||
| 72A | 100A | 150A | 200A | 252A | 300A | 480A | |||
| Inside size(mm) | W | 450 | 500 | 600 | 670 | 700 | 800 | 800 | |
| H | 400 | 450 | 500 | 600 | 600 | 600 | 800 | ||
| D | 400 | 450 | 500 | 500 | 600 | 650 | 750 | ||
| Outside size(mm) | W | 1490 | 1540 | 1640 | 1720 | 1750 | 1850 | 1850 | |
| H | 1790 | 1840 | 1890 | 2000 | 2000 | 2000 | 2200 | ||
| D | 1600 | 1700 | 1830 | 1850 | 1930 | 1980 | 2500 | ||
| Test weight | 5 | 10 | 12 | 15 | 18 | 20 | 20 | ||
| Low Temp Chamber | -55ºC~-10ºC, Pre cooling time: ≤ 60 min from +20ºCto-55ºC | ||||||||
| Test Chamber | -40ºC~+150ºC | ||||||||
| High Temp Chamber | +60ºC~+200ºC ,Within 20 min, Pre-heating time | ||||||||
| Transition time | ≤15S | ||||||||
| Recovery time | High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample | ||||||||
| Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample | |||||||||
| ≤ 5 min | |||||||||
| Ambient Temp. | +5ºC~+35ºC | ||||||||
| Power | AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires | ||||||||
(2) KTS-B Series
| Model |
| ||||||||
| 72B | 100B | 150B | 200B | 252B | 300B | 480B | |||
| Inside size(mm) | W | 450 | 500 | 600 | 670 | 700 | 800 | 800 | |
| H | 400 | 450 | 500 | 600 | 600 | 600 | 800 | ||
| D | 400 | 450 | 500 | 500 | 600 | 650 | 750 | ||
| Outside size(mm) | W | 1490 | 1540 | 1640 | 1720 | 1750 | 1850 | 1850 | |
| H | 1790 | 1840 | 1890 | 2000 | 2000 | 2000 | 2200 | ||
| D | 1600 | 1700 | 1830 | 1850 | 1930 | 1980 | 2500 | ||
| Test weight(KG) | 5 | 10 | 12 | 15 | 18 | 20 | 20 | ||
| Low Temp. chamber | -70ºC~-10ºC ,Pre cooling time: +20ºC~-70ºC ,≤ 60 min | ||||||||
| Test. Chamber | -55ºC~+150ºC | ||||||||
| High Temp. chamber temperature | +60ºC~+200ºC,Preheating time: ≤20 min | ||||||||
| Transition time | ≤15S | ||||||||
| Recovery time | High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample | ||||||||
| Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample | |||||||||
| ≤ 5 min | |||||||||
| Ambient Temp. | +5ºC~+35ºC | ||||||||
| Power | AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires | ||||||||
(3) KTS-D Series
| Model |
| ||||||||
| 72D | 100D | 150D | 200D | 252D | 300D | 480D | |||
| Inside size(mm) | W | 450 | 500 | 600 | 670 | 700 | 800 | 800 | |
| H | 400 | 450 | 500 | 600 | 600 | 600 | 800 | ||
| D | 400 | 450 | 500 | 500 | 600 | 650 | 750 | ||
| Outside size(mm) | W | 1490 | 1540 | 1640 | 1720 | 1750 | 1850 | 1850 | |
| H | 1790 | 1840 | 1890 | 2000 | 2000 | 2000 | 2200 | ||
| D | 1600 | 1700 | 1830 | 1850 | 1930 | 1980 | 2500 | ||
| Test weight | 5 | 10 | 12 | 15 | 18 | 20 | 20 | ||
| Low Temp Chamber | -80ºC~-10ºC, Pre cooling time: ≤ 60 min from +20ºCto-80ºC | ||||||||
| Test Chamber | -65ºC~+150ºC | ||||||||
| High Temp Chamber | +60ºC~+200ºC ,Within 20 min, Pre-heating time | ||||||||
| Transition time | ≤15S | ||||||||
| Recovery time | High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample | ||||||||
| Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample | |||||||||
| ≤ 5 min | |||||||||
| Ambient Temp. | +5ºC~+35ºC | ||||||||
| Power | AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires | ||||||||
Photos show 